BW Series - Brackish Water RO Membrane

Previous
Next

Panamar provides high-performance brackish water reverse osmosis membranes for both residential and commercial water purifiers, ensuring exceptional water quality. Our membranes deliver superior flux and salt rejection rates, effectively removing impurities and producing clean, refreshing drinking water from brackish water sources.


Model

WorkingPressure (psi)

PermeateFlow (GPD)

StableRejection Rate (%)

MinimumRejection Rate (%)

XULP-4040

100

2100(8.0)

99

98

ULP-4021

150

950(3.6)

99

98

ULP-4040

150

2600(10.2)

99.3

99

ULP-8040

150

11500(43.38)

99.3

99

LP-4040

225

2500(9.5)

99.5

99

BW-8040

225

11000(41.6)

99.5

99
  • Testing Conditions
    Testing Pressure……………………………………………100psi (XULP-4040)
    Testing Pressure……………………………………………150 psi (ULP4021, ULP-4040, ULP-8040)
    Testing Pressure……………………………………………225psi (LP-4040, BW-8040)
    Temperature of Testing Solution…………….…… 25℃
    Concentration of Testing Solution (NaCl) ……500ppm, 1500ppm, 2000ppm
    pH Value of Testing Solution…………………………… 7.5
    Recovery Rate of Single Membrane Element…………… 15% (8040-size, 4040-size and 2540-size)
    Recovery Rate of Single Membrane Element…………… 8% (4021-size and 2521-size)
  • Operation limits and conditions
    Max. Working Pressure………………………………………………..600psi (4.14Mpa)
    Max. Feedwater Flow……………………………………………………75gpm (8040-size)
    Max. Feedwater Flow……………………………………………………16gpm (3.6 m3/h) (4040-size)
    Max. Feedwater Temperature………………………………………45℃
    Max. Feedwater SDI……………………………………………………….5
    Residual chlorine Concentration of Feedwater……………………..<0.1ppm
    pH Range of Feedwater during Continuous Operation………..3~10
    pH Range of Feedwater during Chemical Cleaning………………2~12
    Max. Pressure Drop of Single Membrane Element……………….15psi (0.1Mpa)